Mesa Labs Defender Primary Flow Meter
Mesa Labs Defender 510 and Defender 520 are the next generation of the DryCal ® DC-Lite and DryCal ® DC-2 flow Calibrators.
Everything you trust about Mesa Labs DryCal ® technology in the DC-Lite and DC-2 digital flowmeters is available in the Defender 510, 520 & 530 calibrators, which makes it easier than ever to calibrate air sampling pumps. Measure volumetric flow and standardized flow, which correct for temperature and pressure, or calibrate devices that read in mass flow.
Mesa Labs Defenders are true-to-primary flow meters designed to provide lightweight, ultra-compact size, incorporating the industry-leading DryCal technology. Building on the patented DryCal near-frictionless piston technology, the Defender 500 series incorporates features to make it immune to flow source pulsation without the need for in-line dampers.
Like all Mesa Labs calibrators, the Defender calibrator is easy to use. Please turn it on. Connect it to a sampling pump. Start taking readings. It's as simple as that - calibrations within a minute with no messy soap bubble solutions to wait on or clean up after.
The Defender 510, 520, and 530 can take hands-free continuous readings while quickly and accurately setting the flow rate on air sampling pumps or other instruments. The Defender calibrators connect to any PC, and pre- and post-calibration data can be downloaded with the included Optimizer Collect Light software.
Features:
Proven percent of reading accuracy is supported by ISO 17025 accreditation by NVLAP of NIST
Integrated temperature sensors and pressure transducers placed directly in the flow stream for optimum standardized results recording (Bios Defender 520 & 530)
Housed in a molded case with rubber handgrips for a better feel and a sleeker more contemporary look
Large illuminated flow cell viewing window
Navigation menu and a large illuminated graphical display with zoom feature
Rated for extreme cold operation down to -20 ºC
RoHS (Restriction of Hazardous Substances) compliant for Europe
Automatic Shutoff
Choose between flow units mL L cc or cf
Include up to one hundred readings in a group average
Take individual readings continuous hands-free readings or set to read in time intervals anywhere from one minute to sixty minutes between readings
Applications:
Industrial hygiene and air quality applications
Can record ambient temperature and pressure conditions, and has manual controls to standardize readings
Active gas and vapor sampling
Area sampling pump
Bioaerosol sampling
Calibrators and accessories
Particulate sampling
Passive (diffusive) gas and vapor sampling
Flow Range: DryCal Defender Medium (M) Flow: | 50 - 5000 mL/min |
Pressure (Defender 520 only) | mmHg PSI kPa |
Gas Compatibility | Use with non-corrosive non-condensing non-combustible gases less than 70% humidity |
Accuracy: Volumetric (Defender 510 or 520) | ±1.0% |
Volumetric Flow | mL/min L/min cc/min cf/min |
Flow Range: DryCal Defender Low (L) Flow: | 5 to 500 mL/min |
Flow Range: DryCal Defender High (H) Flow: | 300 - 30000 ml/min |
Flow Modes | Suction or Pressure |
Temperature & Pressure Sensors | In the flow stream\nPress: 3.5 mmHg (typical) 7.0 mm (max)\nTemp: 0.8 °C (typical) 1.3 °C (max) |
Reading Styles | Single (manual) Continuous or Burst with averaging function user-selectable from 1 to 100 measurements |
Battery System | 6V rechargeable sealed lead-acid 6-8 hours typical operation |
Battery Operational Time | (5 cycles/min) 3 hours backlight on 8 hours backlight off |
Pressure & Suction Fittings | ¼ ID Hose Barb |
Operating Pressure | (Absolute) 15 PSI |
Laboratory Accreditation | Backed by ISO 17025 accreditation by NVLAP of NIST |
Instrument Certification | RoHS and CE Compliant |